┼Discount10A 220V relay output controls Sauna Thermostat Controller With NTC sensorµ

Producer: MaJack
Identifier: 32707009982
Volume Retail Sales: MaJack piece
Availability: 857 pieces
Last Update : Tue, 20 Oct 2020
£15.09
4.5
(based on 4 user reviews)

Clearance Sale 90% ┼Discount10A 220V relay output controls Sauna Thermostat Controller With NTC sensorµ, finestassuranceCutfor quality from trusted company.

10A 220V relay output controls Sauna Thermostat Controller With NTC sensor

┼Discount10A 220V relay output controls Sauna Thermostat Controller With NTC sensorµ Specification

  • TypeSauna Rooms
  • FeatureComputer Control Panel
  • Model NumberFC-110C-220V10A
  • FunctionDry Steam

┼Discount10A 220V relay output controls Sauna Thermostat Controller With NTC sensorµ Specification & Description Summary

10A 220V relay output controls  Sauna Thermostat Controller With NTC sensor

FC110C-120FC110C-4FC110C-10FC110C-11

Product Features

LCD blue tape crystal display
Power down setting memory function
 

Parameters

Temperature measuring range: 0~100°C
Temperature controlling range: 18~65°C(Custom adjustment range 18-110°C, please leave a message.)

Resolution: 0.1°C
Accuracy: ±1°C
Power: 220VAC±10%, 50HZ
Input: 1 NTC sensor
Output: one 10A relay output controls heating
Consumption :≤3 w
Cut-out size: approx. 104×64(mm); Screen size: 70×29(mm); Panel: 122×74.5×4.6(mm)
Ambient requirements: temperature: -10~60°C; humidity: 20~85% (No condensate)

Buttons Operation Description

Power: On/Off by single click
SET: Single click, enter into setting mode, the temperature value flash and can be adjusted by clicking . Single Click SET button again, time value flash and can be adjusted by clicking . Single click SET button to confirm and exit.

Function Menu

 

Functions

Setting Range

Default

Adjusting Step

Unit

Temp. Setting

18~65

40

1

°C

Time Setting

1~99

60

1

Minute

 

Output Explanation

The Fault Code Table

Wring Diagram

FC110C-10A

Packing List 

1 x temperature controller
1 x User manual

FC110C-10A30A201811021739

 Applications

Khan steam room, Light valley house, the infrared sauna room, steam sauna room.

NOTE

Controller connection load calculation method (three types):
1. Inductive load: The controller connects the compressor, heat pump and other loads.
Calculation formula: working voltage (U) x maximum relay capacity (I)/8;
  For example: The controller connects the compressor voltage is 220V, the maximum capacity of the relay is 30A, the controller connection maximum power cannot exceed 220Vx30A/8=825W.
2. Resistive load: The controller connects heating rods, heating pads, electric water heaters and other loads.
Calculation formula: working voltage (U) x maximum capacity of the relay (I)/2;
For example: The controller connection heating rod voltage is 220V, the maximum capacity of the relay is 10A, the maximum power of the controller connection cannot exceed 220Vx10A/2=1100W.
3. Special load: The controller is connected to incandescent lamps;
Calculation formula: Operating voltage of load (U) x Maximum capacity of relay (I)/15